Home/ Blog/ Seal sizing
Specification 17 September 2026 · 4 min read

Which floor drain seal size do I need

Measure the pipe, not the grating — full size table and survey method

Measure the internal diameter of the pipe below the grating — not the grating, and not the gully body. That one measurement decides the size. The grating is always wider than the pipe beneath it, and the wider upper chamber of a gully is not the reference either. It is the single commonest reason an order comes back as the wrong size.

On a site with dozens of drains across wet rooms, plant rooms and a commercial kitchen, getting this right at survey stage saves a second visit. The procedure below takes about a minute per drain.

How to measure

  1. Lift the grating. Most lift out, or release with a single screw.
  2. Look past the gully body. There is often a wider chamber below the grating; what matters is the pipe below that.
  3. Measure the internal diameter wall to wall through the centre — a tape, a caliper or the measuring tag.
  4. Record it in millimetres and match it to the range in the table.

Between two sizes, specify the smaller one. The silicone ribs expand against the pipe wall; an oversized seal will not enter, while a slightly smaller one still seals.

Size table

Pipe diameter and matching size
MeasuredSizeTypical application
32 mm1.25″Offices, ice machines, cold rooms
38 mm1.5″Wet rooms, en-suites, utility rooms
50–58 mm2″Hotel bathrooms, hospital wards
55–65 mm2.5″Older building stock
75–85 mm3″Commercial kitchens, hotels — the most common size
80–89 mm3″/3.5″Refurbished healthcare facilities
89–100 mm3.5″Industrial kitchens, bakeries
88–102 mm3.5″/4″Food processing
102–110 mm4″Meat processing, breweries, distilleries
120–135 mm5″Car parks, plant rooms
150–156 mm6″Ports, heavy industry

Across Irish commercial stock the 3″ size covers most kitchen and back-of-house gullies; wet rooms and en-suites are usually 1.5″ or 2″.

Gratings, channels and square gullies

The seal sits in the pipe, not in the grating, so the shape above it is irrelevant. Round and square gullies, channel drains in kitchens and shower drains all take the same seal, provided there is a round pipe below for it to seat in. With a channel drain, measure the outlet.

Surveying a whole building

For a multi-drain site it is worth measuring a representative drain in each area — kitchen, wet rooms, plant room, car park — rather than every drain individually. Most buildings use two or three diameters throughout. We can review a drain schedule or a set of photographs and return a quantity breakdown by size; send it through and we will mark it up.

The measuring tag is a keyring with the ranges printed on it — useful for a maintenance team doing the survey themselves.

Installation

No tools, no work on the pipework, no downtime: lift the grating, drop the seal in, replace the grating. About 30 seconds per drain, which is why a full building is typically done in a single shift. Nothing is glued or cut, so units can be removed for cleaning with the extraction tool.

If the drains in question are in a kitchen or food area, the HACCP guidance for drains covers the documentation side; for closed or seasonal buildings see why traps dry out in empty buildings.

Frequently asked questions.

What exactly do I measure on a floor gully?
The internal diameter of the pipe below the grating, wall to wall through the centre. The grating and the wider gully chamber are both larger than the pipe — measuring those is why orders come back oversized.
What if the measurement falls between two sizes?
Specify the smaller size. The silicone ribs expand against the pipe wall, so a slightly smaller seal still seals, while an oversized one will not enter the pipe.
Does it fit square gullies and channel drains?
Yes. The seal sits in the pipe below, so the shape of the grating does not matter. With a channel drain, measure the outlet pipe.
Which size is most common in Irish commercial buildings?
Three inches, around 75 mm, for commercial kitchens and back-of-house gullies. Wet rooms and en-suites are usually 1.5 or 2 inches.
How long does installation take?
About 30 seconds per drain — lift the grating, drop the seal in, replace the grating. No tools and no work on the pipework, so a full building is usually completed in one shift.